It has been designed to be used for torque verification in assembly and manufacturing.
MultiTorq is a small compact and accurate electronic meter capable of acquiring data from a variety of torque sensors and logging values into memory. It has been designed to be used for torque verification in assembly and manufacturing.

MultiTorq can be used for auditing and process reporting while giving statistical process control (SPC) of stored data.

MultiTorq can also be used with in-line transducers resulting in the accuracies associated with assembling with an electronic torque wrench.
 
Features
  • Versatile Battery operated, light weight, with available ranges from 2-20 in-oz to 150-1500 ft-lb, and seven units of measure, in-oz, in-lb, ft-lb, Nm, dNm, mKg, or cmKg.
  • The MultiTorq¢â system can be used with sockets, extensions, universal joints, ratcheting drivers or any of these combined
  • PC Statistical Analysis Output: Down load histogram, minimum and maximum reading, mean, sigma N, sigma, CP, Cpk, % error, number of readings under and over tolerance
  • Serial Port Interface with Computer or Printer: True RS-232 communications port for down loading to computer or serial printer. Also configurable to Mitutoyo statistical printer protocol
  • Smart Sensors: Built-in EEprom memory chip identification and calibration factors. Factory calibrated, a sensor retains its accuracy with all MultiTorq¢â meters, just plug in the desired sensor. Periodic re-calibration is necessary
  • 120/220 Vac 60 Hz Adapter: Rechargeable battery and handy belt clip allows you to take it to the task
  • Visual and Audio Cues: Analog bar graph at top of display provides a live indication of applied torque.
  • An over warning flag comes on to indicate maximum sensor range has been exceeded. Green MIN LED indicate lower tolerance has been achieved and a Red MAX LED indicates upper tolerance has been exceeded. Audio alarm produces a distinctive 2Khz tone.
  • Audio output jack for optional head phones in a noisy environment.
  • Track or Peak Mode: Track mode displays applied torque value and Peak mode displays highest torque value
  • Easily Calibrated: Customer calibration supports ISO9000. Instructions for step-by-step calibration provided in the user¡¯s manual
  • Data Acquisition: Store and recall up to 3,500 readings. An internal memory backup battery retains setup and last memory data for up to ten years
  • Analog Bar Graph
  • Super Twist Liquid Crystal Display
  • 7 Torque Units
  • Track Mode
  • Peak-Hold Mode
 
SPECIFICATIONS
Accuracy ¡¾1% of reading
Units of Measure ft-lb, in-lb, in-oz, Nm, dNm, mKg, and cmKg
Statistical Analysis Max, Min, Range, Mean, Sigma n, Sigma, Cp,
Cpk, % Error, -NoGo, and +NoGo
Display Capacity 4 digit, 8,000 counts
Dimensions  3" wide, 2.5" high (3" w/belt clip), 6" deep
Serial Output Port RS-232 (true), 300-19.2K baud and
Mitutoyo (statistical protocol)
Histogram Lower set limit, upper set limit, and 10 divisions
 
CAT NO. MODEL DEscRIPTION AVAIL PRICE 
CD1600   1600-MT   METER INCLUDING CASE & CHARGER   Yes   3,877,200 
CD201O   201-O-MT   TRANSDUCER RANGE 2-20 IN OZS   Yes   1,242,000 
CD101I   101-I-MT   TRANSDUCER RANGE 1-10 IN. LBS   Yes   1,242,000 
CD501I   501-I-MT   TRANSDUCER RANGE 5-50 IN LBS   Yes   857,520 
CD2001I   2001-I-MT   TRANSDUCER RANGE 20-200 IN LBS   Yes   717,120 
CD2503F   2503-F-MT   TRANSDUCER RANGE 25-250 FT LBS   Yes   1,242,000 
CD6004F   6004-F-MT   TRANSDUCER RANGE 60-600 FT LBS   Yes   1,188,000 
CD15005F   15005-F-MT   TRANSDUCER RANGE 100-500FT/LBS   Yes   2,797,200 
CD16003   1600-30   OPTIONAL HEAD PHONES FOR Torque Data Acquisition System   Yes   108,000 
CD16001   1600-10   OPTIONAL CABLE: RS232 TO SERIAL PRINTER FOR Torque Data Acquisition System   Yes   154,008

 

CD16002   1600-20   OPTIONAL CABLE RS232 TO PC FOR Torque Data Acquisition System   Yes   154,008 
CD1121   2000-112-1   OPTIONAL SERIAL PRINTER FOR Torque Data Acquisition System   Yes   1,998,000
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ