ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > ¿Âµµ Temperature > ¿Âµµ°è Thermometer
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
BN315009 Logging RTD Thermometer
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
ThermoLogR RTD Thermometer
Infrared Printer is ideal for on-site documentation. Transfer data without the use of cables-just position printer within 12" (30cm) of the top of the thermometer. Set print interval rate from once every 3 seconds to once every 60 minutes. To print in intervals longer than 10 minutes the printer must be powered by an AC adapter

ThermoLogR Thermistor Thermometer
Infrared Printer is ideal for on-site documentation. Transfer data without the use of cables-just position printer within 18" (45cm) of the top of the thermometer. Set print interval rate from once every 3 seconds to once every 60 minutes. To print intervals longer than 10 minutes the printer must be powered by an AC adapter

 
ThermoLogR RTD Thermometer
  • Log up to 1000 readings of temperature with time and date
  • Transfer data to an infrared printer or to your computer via infrared RS-232 adapter
  • CAL button enables you to field calibrate the meter
  • Switch selectable temperature units ¡ÆF/¡ÆC
  • Simultaneously monitor current, minimum and maximum readings
  • Rugged ABS plastic case and sealed silicone membrane keypad for an IP54 splash proof rating
  • RS-232 interface connects to your computer 9-pin serial port for easy uploading of data. Use with most popular RS-232 programs including Windows Terminal¢ç or Windows 95/98 Hyperterminal
  • Accepts 100 ohm platinum RTD sensors (order separately)
 
ThermoLogR Thermistor Thermometer
  • Log up to 1000 readings of temperature with time and date
  • Transfer data to an infrared printer or to your computer via the optional infrared RS-232 adapter
  • CAL button enables you to field calibrate the meter
  • Switch selectable temperature units ¡ÆF/¡ÆC
  • Simultaneously monitor current, minimum and maximum readings
  • Rugged ABS plastic case and sealed silicone membrane keypad for an IP54 splash proof rating
  • RS-232 interface connects to your computer 9-pin serial port for easy uploading of data. Use the most popular RS-232 programs including Windows Terminal¢ç or Windows 95/98 Hyperterminal
  • Accepts 400 or 700 series thermistor probes (sold separately)
 
SPECIFICATIONS
Model

Type

Range

Accuracy

Resolution

Probe Connection, type

BN315009

Logging RTD
Thermometer

-330¡ÆF to 2210¡ÆF
(-201 to 1210¡ÆC)

¡¾0.06¡ÆF (¡¾0.03¡ÆC)

0.01¡Æ from -99.99¡Æ to +99.99¡Æ
0.1¡Æ from - 100.0¡Æ to -330¡Æ and
100.0 to 999.9¡Æ; 1¡Æ above 1000¡Æ

3-pin(round);
100¥Ø platinum
RTD

BN315018

Logging
Thermistor
Thermometer

YSI 400 Series Probes
-40¡Æ to +302¡ÆF
(-40¡Æ to +150¡ÆC)
YSI 700 Series Probes
-40¡Æ to +212¡ÆF
(-40¡Æ to +100¡ÆC)

0.01¡Æ or 0.1¡Æ autoranging
to 0.1¡Æ above 99.99¡Æ

1/4" phone jack;
YSI 400 or 700
series

Display: 0.4" H for top LCD, 0.2" H for bottom LCD; Output: infrared; Power: two AA batteries (included), Battery life approx. 300 hours; Low battery indicator: yes; Dimensions: 3.3"W x 6.2"H x 1.2"D (84mm W x 158mm H x 30mm D); Shipping weight: 1 lb (0.5kg)

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
BN315009   WD-60010-85   ThermoLogR RTD Thermometer   Yes   541,620
BN315018   WD-60010-75   THERMISTOR THERMOMETER   Yes   541,620
BN315022   WD-9700-52   OPTIONAL 115VAC adapter FOR ThermoLogR RTD and ThermoLogR Thermistor Thermometers   Yes   60,588

 

BN315023   WD-9700-55   OPTIONAL 230VAC adapter FOR ThermoLogR RTD and ThermoLogR Thermistor Thermometers   Yes   82,620

 

BN315024   WD-6700-90   OPTIONAL Carrying case FOR ThermoLogR RTD and ThermoLogR Thermistor Thermometers   Yes   49,572

 

BN315025   WD-10374-50   OPTIONAL Infrared printer with one roll of paper FOR ThermoLogR RTD and ThermoLogR Thermistor Thermometers   Yes   695,844

 

BN315026   600-0082   OPTIONAL Printer adapter 70-240VAC 50/60Hz, 6 ft. cord FOR ThermoLogR RTD and ThermoLogR Thermistor Thermometers   Yes   73,440

 

BN315027   WD-37455-82   OPTIONAL Replacement paper (3 pack) FOR ThermoLogR RTD and ThermoLogR Thermistor Thermometers   Yes   22,032

 

BN315028   WD-9700-85   OPTIONAL RS-232 interface adapter (software not included) FOR ThermoLogR RTD and ThermoLogR Thermistor Thermometers   Yes   174,420

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ